Eight weekly 8 Hz sessions versus sham

Q: Did eight weekly sessions beat sham on function?

A: A sham-controlled trial published in 2025 found that eight weekly 8 Hz sessions left adults with knee, shoulder, or lumbar pain able to do more, and in less pain, than a sham device. The gap was still there twelve weeks after the first session.

Who came to the orthopaedic clinic

One hundred twenty-six adults, age 18 or older, came to one orthopaedic clinic with pain from a rotator cuff, the lumbar spine, or the knee. Forty-three had rotator cuff enthesopathy, fifty-two had lumbar spondyloarthrosis, and thirty-one had knee osteoarthritis. Pain had to be at least 4 on a 0-to-10 scale, and the problem had to have lasted at least six weeks. Visits ran from January 2016 to March 2017. The report was published online on 28 November 2025.

Half were assigned to the real applicator and half to a sham device that looked and sounded the same. Sixty-three people started in each group. Three left the real-applicator group and two left the sham group, so the comparison rests on 60 and 61 people.

Eight weekly sessions, real or sham

Each person had eight sessions, once a week, for 20 minutes. The real applicator was a MAGNETOLITH unit from STORZ Medical, set at 8 Hz. That name is the clinic tool in this trial, not a brand to chase. For a knee, the applicator sat over the front of the knee while the knee was slightly flexed. For a shoulder, it sat over the tendon insertion. For the lumbar spine, it sat over the painful segment. The sham group had the same schedule on a device that did not deliver the field.

The two scores that mattered were how much pain they felt, on a 0-to-10 line, and how well they could do ordinary physical tasks, on the physical part of a short health questionnaire. Both were taken at the start, at six weeks, and at twelve weeks.

Function rose and pain fell

At six weeks, the physical-function score was 42.9 in the real-applicator group and 38.6 in the sham group. The gap was significant, P < 0.001. Pain was 2.8 against 4.3, also P < 0.001.

At twelve weeks the gap was still there. Physical function was 45.5 against 38.7. Pain was 2.2 against 4.2. Both comparisons were P < 0.001. People who started with the real applicator could do more, and they hurt less, than the people who had sat with the sham device.

What did not differ

The mental-health score on that same questionnaire did not differ between the groups at six weeks or at twelve weeks. The P values were 0.19 and 0.27. A reader should not take this trial as a mood result.

Mild discomfort and skin redness were more common with the real applicator than with the sham device. The paper does not describe a serious injury from the sessions.

A clinic course, not a promise for every joint

The visits were in one orthopaedic clinic, and the people had three different diagnoses. The paper does not split the pain and function scores by knee, shoulder, and lumbar spine, so the gap is for the mixed group, not a separate proof for each joint. The course was eight weeks, and the last score was at twelve weeks. It does not say what the scores looked like a year later.

Nikola Tesla's coil is the old lineage: a pulse close to the body, in a room where someone can sit still. If a knee, a shoulder, or the low back is the place that asks for attention, open a short session for that site and sit with it. The 8 Hz row on this page is the clinic trial setting, so you can see the number they used. The field strength is not in the tone.

The paper

Lennart Gerdesmeyer, Rainer Burgkart, Rüdiger von Eisenhart-Rothe, Johannes Vester, and Karsten Hollander. Extracorporeal magnetotransduction therapy (EMTT) for management of musculoskeletal disorders: A double-blind, placebo-controlled, randomised trial. Journal of Orthopaedics and Traumatology. 2026. Published online 28 November 2025.

Read the paper. PubMed record: PMID 41313312.

KYMA is working to establish a science-based podcast, because reliable information about this topic is almost impossible to find on ordinary social media.

ResultWhat the paper reported
Physical function at six weeks42.9 after the real applicator, and 38.6 after sham (P < 0.001).
Pain at six weeks2.8 on a 0-to-10 line after the real applicator, and 4.3 after sham (P < 0.001).
Twelve weeksPhysical function 45.5 against 38.7, and pain 2.2 against 4.2. Both gaps were P < 0.001.

Open these library sets if you want a stored program for the same topic. They are here because they match the subject of the paper. A magnetic-field setting is not stored in the tone.

Frequently asked questions

Did eight weekly sessions ease joint pain more than sham?

Yes. In this sham-controlled trial, eight weekly 8 Hz sessions left the real-applicator group with a physical-function score of 42.9 at six weeks, against 38.6 after sham, and a pain score of 2.8 against 4.3. At twelve weeks the scores were 45.5 against 38.7 for function, and 2.2 against 4.2 for pain. Each of those gaps was P < 0.001.

Who took part, and what did the two groups receive?

One hundred twenty-six adults with rotator cuff pain, lumbar spondyloarthrosis, or knee osteoarthritis. Sixty-three started on the real applicator and sixty-three on a sham device. Each person was offered eight sessions of 20 minutes, once a week. The comparison uses the 60 and 61 people who stayed in.

Which set should I open for the 8 Hz clinic setting?

Open the 8 Hz trial-setting row first. That is the number the clinic set for twenty minutes, once a week, for eight sessions. Then open Knee Pain, Joint Pain, Back Pain, and Shoulder Injuries, because those match the knee, the joint, the lumbar spine, and the shoulder in this trial. None of those four already stores 8 as a whole number, so they match the body site rather than the clinic number. The field strength is not in the tone. This trial did not test those library rows.