10 Hz plus ankle brace versus sham coil over 4 weeks

Q: Did a 10 Hz coil plus an ankle brace move the ankle farther than a sham coil over 4 weeks?

A: A 2026 randomized trial in 60 older adults after a recent stroke found that 4 weeks of a 10 Hz scalp coil plus a custom ankle brace improved active ankle motion more than the same brace with a sham coil, and more than usual rehabilitation. The combined group also gained more walking speed over those 4 weeks.

Who took part

Sixty adults, ages 60 to 80, joined at Jinhua Municipal Central Hospital in Zhejiang, China. Each person was 1 to 6 months past a first stroke and walked with a dropped, turned-in foot. The average age in each group was about 69, and 36 of the 60 were men. Twenty people were assigned to each of three groups. They could stand with balance and walk at least 10 meters, with supervision if they needed it.

What the three groups received over 4 weeks

Everyone had usual stroke rehabilitation for 4 weeks. One group also wore a sham brace and had a sham coil. The second group wore a custom 3D-printed ankle-foot brace and had a sham coil. The third group wore that same brace and received a real 10 Hz coil held to the motor cortex on the injured side of the head.

Each coil session lasted 20 minutes, once a day, 5 days a week. The pulse came in 2-second trains with 8-second rests, 2,400 pulses in all, set between 80 and 120 percent of that person's resting motor threshold. The device was a figure-8 coil on a stimulator from Jiangxi Brain Regulation Company. For the sham, the coil was turned on its side so the sound stayed and the intended pulse did not. The people scoring the tests did not know which group someone was in.

How much the ankle and the walk changed

Active ankle motion was the main result. Over 4 weeks, dorsiflexion rose by 6.20 degrees in the combined group, from 5.85 to 12.05. The brace with a sham coil rose by 4.65 degrees. Usual rehabilitation rose by 3.95 degrees. The combined gain was larger than the brace-only gain (p = 0.022) and larger than usual rehabilitation (p < 0.001). Eighteen of 20 people in the combined group gained at least 4 degrees. That was 12 of 20 with the brace alone, and 8 of 20 with usual rehabilitation.

Plantarflexion rose by 12.75 degrees with the coil plus the brace, 8.70 degrees with the brace and a sham coil, and 6.10 degrees with usual rehabilitation. Walking speed rose by 0.35 meters per second in the combined group, from 0.45 to 0.80. The other two groups rose by 0.20 and 0.21 meters per second. The paper also reported stronger signals from the shin and outer-ankle muscles, and higher motor-cortex excitability, in the combined group.

What did not separate the groups

The brace alone did not beat usual rehabilitation on active dorsiflexion (p = 0.437). Spasticity and balance improved in both brace groups compared with usual rehabilitation, and the added coil did not separate those two brace groups on those scores. The overall group difference on the 10-meter walk was not significant (p = 0.221), even though the size of the speed gain was larger when the coil was real. This was one hospital, 60 people, and 4 weeks, with no later visit to see how long the gain lasted. There was no coil-only group, so the paper can say the coil added something to the brace. It cannot say how the coil would have done by itself. No serious adverse event was reported.

Read the paper, then sit with a tone

Yuting Zhang and Hehe Chen share first place on the paper. Rui Xu, Lingyu Zhu, and Siyuan Song are coauthors. Weixin Zhu is the corresponding author at Jinhua Municipal Central Hospital. The full text is in Frontiers in Neurology, 13 October 2026.

When you want a quiet session after the numbers, open the 10 Hz trial setting for 20 minutes, then a gait or stroke set if that is the work you are sitting with. The hospital coil is their tool. Your session is the library, the headphones, or the coil you already use at home.

KYMA is working to establish a science-based podcast, because reliable information about this topic is almost impossible to find on ordinary social media.

ResultWhat the paper reported
Ankle liftCombined group gained 6.20 degrees of active dorsiflexion in 4 weeks, versus 4.65 with the brace and a sham coil and 3.95 with usual rehabilitation.
Ankle pushCombined group gained 12.75 degrees of active plantarflexion, versus 8.70 with the brace and a sham coil and 6.10 with usual rehabilitation.
Walking speedCombined group gained 0.35 meters per second, from 0.45 to 0.80, versus 0.20 and 0.21 in the other two groups.
Who gained at least 4 degrees18 of 20 in the combined group, 12 of 20 with the brace and a sham coil, and 8 of 20 with usual rehabilitation.

Start with the trial-setting row for the 10 Hz, 20-minute coil session, then open a gait, stroke, or muscle set if you want a stored program for the same kind of walking work. The hospital coil's field strength is not in the tone.

Frequently asked questions

How long was each 10 Hz session?

Twenty minutes, once a day, 5 days a week, for 4 weeks. The coil sat at 10 Hz in 2-second trains with 8-second rests.

Which library sets match this ankle and walking study?

Open 10 Hz Ankle Brace Stroke Trial first, because that row stores the 10 Hz setting from this 4-week ankle trial, for 20 minutes. Then open Gait Disorders [Neurologic], Stroke, Muscle Spasticity, and Muscle Recovery Accelerator. They match the walking, stroke, and muscle subject of the paper, which is why they are on this page. Those four do not store 10 Hz. The study did not test these library sets. The coil's field strength is not in the tone.

How did the brace alone compare with the brace plus the coil?

On the main ankle-lift measure, the brace plus the 10 Hz coil gained more than the brace with a sham coil: 6.20 degrees versus 4.65. The brace alone did not separate from usual rehabilitation on that same lift. On the push-off and on walking speed, the combined group was also ahead of the brace alone.

Loading KYMA…